Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Guidance on Safe Use

Guidance on Safe Use

Currently viewing:

Administrative data

First-aid measures

Inhalation:

Remove to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen. Get medical attention immediately.

Ingestion:

If swallowed, DO NOT INDUCE VOMITING. Give large quantities of water. Never give anything by mouth to an unconscious person. Get medical attention immediately.

Skin Contact:

Immediately flush skin with plenty of water for at least 15 minutes while removing contaminated clothing and shoes. Get medical attention immediately. Wash clothing before reuse. Thoroughly clean shoes before reuse.

Eye Contact:

Immediately flush eyes with plenty of water for at least 15 minutes, lifting lower and upper eyelids occasionally. Get medical attention immediately.

Fire-fighting measures

Fire:

Not considered to be a fire hazard.

Explosion:

Not considered to be an explosion hazard.

Fire Extinguishing Media:

Use any means suitable for extinguishing surrounding fire.

Special Information:

Use protective clothing and breathing equipment appropriate for the surrounding fire.

Accidental release measures

Ventilate area of leak or spill. Keep unnecessary and unprotected people away from area of spill. Wear appropriate personal protective equipment as specified in Section 8.

Spills: Pick up and place in a suitable container for reclamation or disposal, using a method that does not generate dust.

Avoid release to the environment. US Regulations (CERCLA) require reporting spills and releases to soil, water and air in excess of reportable quantities. The toll free number for the US Coast Guard National Response Center is (800) 424-8802.

Handling and storage

Keep in a well closed container stored under cold to warm conditions, 2 to 40 C, (36 to 104F). Protect against physical damage. Containers of this material may be hazardous when empty since they retain product residues (dust, solids); observe all warnings and precautions listed for the product.

Transport information

Land transport (UN RTDG/ADR/RID)

UN number:
2331
Shipping information
Proper shipping name and description:
zinc chloride , anhydrous
Class or division:
Class 8: Corrosive substances
Packing group:
Packing group III: Substances presenting low danger
Labels:
GHS05: Corrosive
SpecialProvisionsopen allclose all

Inland waterway transport (UN RTDG/ADN(R))

UN number:
2331
Shipping information
Proper shipping name and description:
zinc chloride , anhydrous
Class or division:
Class 8: Corrosive substances
Packing group:
Packing group III: Substances presenting low danger
Labels:
GHS05: Corrosive
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

UN number:
2331
Shipping information
Proper shipping name and description:
zinc chloride, anhydrous
Class or division:
Class 8: Corrosive substances
Packing group:
Packing group III: Substances presenting low danger
Labels:
GHS05: Corrosive
Marine pollutant
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

UN number:
2331
Shipping information
Proper shipping name and description:
zinc chloride , anhydrous
Class or division:
Class 8: Corrosive substances
Packing group:
Packing group III: Substances presenting low danger
Labels:
GHS05: Corrosive
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Airborne Exposure Limits:

Zinc chloride:

OSHA Permissible Exposure Limit (PEL):

1 mg/m3 (TWA) 8H, as fume.

ACGIH Threshold Limit Value (TLV):

1 mg/m3 (TWA); 2 mg/m3 (STEL) for fume

Ventilation System:

A system of local and/or general exhaust is recommended to keep employee exposures below the Airborne Exposure Limits. Local exhaust ventilation is generally preferred because it can control the emissions of the contaminant at its source, preventing dispersion of it into the general work area. Please refer to the ACGIH document, Industrial Ventilation, A Manual of Recommended Practices, most recent edition, for details.

Personal Respirators (NIOSH Approved):

If the exposure limit is exceeded, a full facepiece respirator with dust/mist filter may be worn up to 50 times the exposure limit or the maximum use concentration specified by the appropriate regulatory agency or respirator supplier, whichever is lowest. For emergencies or instances where the exposure levels are not known, use a full-facepiece positive-pressure, air-supplied respirator. WARNING: Air purifying respirators do not protect workers in oxygen-deficient atmospheres.

Skin Protection:

Wear impervious protective clothing, including boots, gloves, lab coat, apron or coveralls, as appropriate, to prevent skin contact.

Eye Protection:

Use chemical safety goggles and/or full face shield where dusting or splashing of solutions is possible. Maintain eye wash fountain and quick-drench facilities in work area.

Stability and reactivity

Stability:

Stable under ordinary conditions of use and storage.

Hazardous Decomposition Products:

When heated to decomposition it emits toxic fumes of chlorine and zinc oxide.

Hazardous Polymerization:

Will not occur.

Incompatibilities:

Cyanides and sulfides, powdered zinc. When mixed with potassium, a weak explosion will occur on impact.

Conditions to Avoid:

Incompatibles.

Disposal considerations

Whatever cannot be saved for recovery or recycling should be managed in an appropriate and approved waste disposal facility. Processing, use or contamination of this product may change the waste management options. State and local disposal regulations may differ from federal disposal regulations. Dispose of container and unused contents in accordance with federal, state and local requirements.