Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2017-11-08
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study with acceptable restrictions
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Qualifier:
according to guideline
Guideline:
ISO 3679 (Determination of flash point - Rapid equilibrium closed cup method)
GLP compliance:
no
Other quality assurance:
ISO/IEC 17025 (General requirements for the competence of testing and calibration laboratories)
Remarks:
ISO 9001:2008
Type of method:
equilibrium method closed cup
Flash point apparatus:
Setaflash apparatus
Key result
Flash point:
87 °C
Atm. press.:
1 013 hPa

Test Conditions


Humidity (rel.): 44 %  


Room temperature: 23°C


Atmospheric pressure: 96.3 kPa


 






























































Test



Test series 1 temperature [°C]



Result yes(+) / no(-)



Test series 2 temperature [°C]



Result yes(+) / no(-)



1



77



-



80



-



2



79



-



81



-



3



81



-



82



-



4



83



-



83



-



5



85



-



84



-



6



86



+



85



+



7



86



+



85



+



 


























Test series



Measured value [°C]



Corrected value [°C]



1



86



87.25



2



85



86.25



Mean value



 



87



*The mean value is calculated from test 1 and 2 and rounded to ± 0.5°C


 

Interpretation of results:
GHS criteria not met
Conclusions:
A flash point value of 87°C at 1013 hPa was determined for the substance using a relevant test method. The result is considered to be reliable.

Description of key information

Flash point: 87°C at 1013 hPa (ISO 3679)

Key value for chemical safety assessment

Flash point at 101 325 Pa:
87 °C

Additional information

A measured flash point of 87°C at 1013 hPa was determined for the registration substance using a rapid equilibrium method in accordance with ISO 3679 Test Method and in compliance with a known quality system (ISO 9001:2008). The result is considered to be reliable, and the study is selected as key study.

In available secondary sources to which reliability could not be assigned, flash point values of 82°C and 90°C at 1013 hPa were reported for the substance.

A measured flash point of 87°C at 1013 hPa and a measured boiling point of 198.4°C at 1013 hPa, indicate that the substance should not be classified for flammability according to the criteria of Regulation (EC) No. 1272/2008.