Registration Dossier

Diss Factsheets

Physical & Chemical properties

Auto flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
auto-ignition temperature (liquids)
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Study performed according to GLP and EC guideline A15
Qualifier:
according to guideline
Guideline:
EU Method A.15 (Auto-Ignition Temperature (Liquids and Gases))
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Auto-ignition temperature:
330 °C
Atm. press.:
1 001 - 1 015 mBar
Remarks on result:
other:

Test run no. Lowest temperature in °C Quantity of sample in mL Ignition delay time in s
1st test series 335 0.26 10
2nd test series 335 0.16 8
3rd test series 337 0.29 9

From these test runs, a corrected (according to EN 14522) auto-ignition temperature of 330°C results.

Conclusions:
The auto-ignition temperature for the test substance is 330°C.
Executive summary:

The auto-ignition temperature for the test substance was found to be 330 °C in a test according to EU method A.15.

Description of key information

Autoflammability: 330°C at 1001-1015 mbar.

Key value for chemical safety assessment

Autoflammability / Self-ignition temperature at 101 325 Pa:
330 °C

Additional information

The auto-ignition temperature for the test substance was found to be 330 °C in a test according to EU method A.15.