Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
1997-10-16
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods with acceptable restrictions
Qualifier:
equivalent or similar to guideline
Guideline:
other: ASTM E1782
Deviations:
not specified
Principles of method if other than guideline:
Measurement of vapour pressure with DSC ( Differential Scanning Calorimetry)
GLP compliance:
not specified
Type of method:
other: differential scanning calorimetry (DSC)
Temp.:
37.9 °C
Vapour pressure:
4.02 mBar
Remarks on result:
other: measured result, not calculated by Antoine fit or Clausius Clapeyron
Temp.:
41.1 °C
Vapour pressure:
5.01 mBar
Remarks on result:
other: measured result, not calculated by Antoine fit or Clausius Clapeyron
Temp.:
46.9 °C
Vapour pressure:
7.03 mBar
Remarks on result:
other: measured result, not calculated by Antoine fit or Clausius Clapeyron
Temp.:
51 °C
Vapour pressure:
8.53 mBar
Remarks on result:
other: measured result, not calculated by Antoine fit or Clausius Clapeyron
Temp.:
53.1 °C
Vapour pressure:
10.01 mBar
Remarks on result:
other: measured result, not calculated by Antoine fit or Clausius Clapeyron

- The test substance vapour pressure was measured in the temperature range of 38 °C up to 53 °C. Extrapolation was carried out, showing that error increases drastically with too far extrapolation.


- The measurements were performed at tempertaures that are far above the SADT of the tets substance. Handeling the test substance at these temperatures while doing the DSC test was possible because very low amounts were used and the measurements were very fast.

Conclusions:
At temperatures between 38 °C to 53 °C vapour pressure between 4.02 to 10.01 mBar were measured for tert-butyl peroxypivalate (TBPPI).
Executive summary:

The vapour pressure of TBPPI, was measured at various temperatures with vaccum DSC. The temperature range of the method is limited. The lower pressure limit depends on the capacity of the vacuum pump (about 0.5 mbar), the lower temperature limit of the DSC-apparatus (25 °C) or by the melting point of the product. The upper limit depends on the thermal stability of the product. In the case Trigonox 25-C75 the lower pressure is limited by the pump capacity. The vapour pressure of TBPPI in the temperature range of 38 °C to 53 °C was measured although the temperatures were above the SADT. That was feasible in this DSC test as the amounts used were low and the measurements were very fast. At temperatures between 38 °C to 53 °C vapour pressure between 4.02 to 10.01 mBar was measured for tert-butyl peroxypivalate (TBPPI). Extrapolation of the obtained results showed that the error in the pressure will increase at extrapolation.

Description of key information

At temperatures between 38 °C to 53 °C vapour pressure between 402 to 1001 Pa were measured for tert-butyl peroxypivalate (TBPPI).

Key value for chemical safety assessment

Vapour pressure:
119 Pa
at the temperature of:
20 °C

Additional information

The vapour pressure of tert-butyl peroxypivalate (TBPPI), 95 % purity, was measured at various temperatures with vacuum DSC. The vapour pressure of the test substance in the temperature range of 38 °C to 53 °C was measured although the temperatures were above the SADT. That was feasible in this DSC test as the amounts used were low and the measurements were very fast. At temperatures between 38 °C to 53 °C, vapour pressure between 4.02 to 10.01 mBar was measured for TBPPI. Extrapolation of the obtained results showed that the error in the pressure will increase at extrapolation.

Vapoure pressure was calculated to be 169 Pa and 119 Pa at 25 °C and 20 °C, respectively.