Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Description of key information

The subsance is not considered as flammable material.

Key value for chemical safety assessment

Flammability:
not classified

Additional information

Flammable gases

The test item is a liquid at ambient conditions. This hazard class is only applicable for gases. Thus, the substance was not considered for classification as flammable gas.

 

Flammable liquid

The test on the flammability (Regulation (EC) No 440/2008 method A.10) was not performed as the test item is a liquid. For liquids the primary value for ease of ignition is the flash point conducted using Method A9 ‘Flash Point Method’ of Council Regulation (EC) No 440/2008. The result of the Flash Point test is used to allocate a liquid substance into the appropriate flammability class. The flash point of the test item was determined to be 70 °C (refer to IUCLID Section 4.11). Thus, the substance doesn't have to be classified as flammable liquid according to Regulation (EC) No 1272/2008.

 

Flammable solids

The test item is a liquid at ambient conditions. This hazard class is only applicable for solids. Thus, the substance was not considered for classification as flammable solid.

 

Pyrophoric solids

The test item is a liquid at ambient conditions. This hazard class is only applicable for solids. Thus, the substance was not considered for classification as pyrophoric solid.

 

Pyrophoric liquids

In accordance with section 2.9.4 Annex I of Regulation (EC) No 1272/2008 and ECHA guidance on the application of CLP Criteria section 2.9.4.2 the classification procedure for pyrophoric liquids need not to be applied when experience in manufacture or handling shows that the liquid does not ignite spontaneously on coming into contact with air at normal temperatures (i.e. the liquid is known to be stable at room temperature for prolonged periods of time (days)). Based on the experience in handling and use the substance is not known to ignite spontaneously when coming into contact with air at normal temperatures. Thus, no study was conducted and the substance was not considered for classification as pyrophoric liquid.

 

Substances which, in contact with water, emit flammable gases

In accordance with column 2 of REACH Annex VI and with Regulation (EC) No 1272/2008 Annex I section 2.12.4 and ECHA guidance on the application of CLP Criteria section 2.12.4.2 the classification procedure for this hazard class need not to be applied. Based on the experience in handling and use the substance does not react with water and in addition the test substance is not pyrophoric. Thus, no study was conducted and the substance was not considered for classification.

 

Self-heating substances and mixtures

In accordance with ECHA guidance on the Application of the CLP Criteria section 2.11.4.2 and ECHA guidance on IR/CSA chapter R.7a section R7.1.10.7 the test does not to be conducted as in general liquids are not classified as self-heating since the phenomena applies only to solids and the test method is not applicable to liquids according to ECHA guidance on the Application of the CLP Criteria section 2.11.4.2.

 

Flammable Aerosols

Section 2.4.2 of Guidance on the application on the CLP Criteria state as follows: “Aerosols, this means aerosol dispensers, are any non-refillable receptacles made of metal, glass or plastics and containing a gas compressed, liquefied or dissolved under pressure, with or without a liquid, paste or powder, and fitted with a release device allowing the contents to be ejected as solid or liquid particles in suspension in a gas, as a foam, paste or powder or in a liquid state or in a gaseous state." Thus, as the substance does not meet the definition for aerosol, the test for aerosols was waived. Consequently the substance has not to be considered for classification for this hazard class.

 

In conclusion, the substance doesn't have not to be considered as flammable gas, flammable liquid, flammable solid, flammable in contact with water, flammable aerosol, pyrophoric solid, pyrophoric liquid or self-heating substance.

Justification for classification or non-classification

In accordance with Annex I, Section 2.1, Section 2.2, Section 2.3, Section 2.7, Section 2.9, Section 2.10 Section 2.11, Section 2.12 of Regulation (EC) No 1272/2008 and UN GHS Rev 6 (2015) the substance has not to be classified as readily combustible solid in class 4 Division 4.1, self-heating substance in Class 4 Division 4.2, substances which in contact with water emit flammable gases in Class 4 Division 4.3, pyrophoric liquid, pyrophoric solid in class 4 Division 4.2, flammable gases in class 2 or as aerosol in class 2.