Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study with acceptable restrictions
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Version / remarks:
2002
Qualifier:
according to guideline
Guideline:
ISO 13736:1997 (Petroleum products and other liquids - Determination of flash point - Abel closed cup method)
Version / remarks:
1997
Qualifier:
according to guideline
Guideline:
ISO No., other: EN ISO 2592
GLP compliance:
no
Type of method:
closed cup
Remarks:
and open cup
Key result
Remarks on result:
other: no flash point detectable

DIN EN ISO 2719: no flash point detectable, the pilot flame expires at 68°C.

DIN EN ISO 13736: no flash point detectable, the pilot flame expires at 60°C.

DIN EN ISO 2592: no flash point detectable, the pilot flame expires at 80°C

Description of key information

No flash point detectable.

Key value for chemical safety assessment

Additional information

Testing a 41% aqueous solution, no flashpoint is detectable and the pilot flame is put out at 60 - 80 °C, regardless of the test method applied.