Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Toxicological information

Acute Toxicity: inhalation

Currently viewing:

Administrative data

Endpoint:
acute toxicity: inhalation
Type of information:
experimental study
Adequacy of study:
supporting study
Reliability:
4 (not assignable)
Rationale for reliability incl. deficiencies:
other: No details if guideline followed or if to GLP, limited reporting on methods and results

Data source

Reference
Reference Type:
other company data
Title:
Unnamed
Year:
1975
Report date:
1975

Materials and methods

Principles of method if other than guideline:
Acute inhalation toxicity was assessed in male rats following a 7-hr exposure to DEIPA saturated air.
GLP compliance:
not specified
Test type:
standard acute method
Limit test:
yes

Test material

Constituent 1
Chemical structure
Reference substance name:
1-(N,N-bis(2-hydroxyethyl)amino)propan-2-ol
EC Number:
229-764-5
EC Name:
1-(N,N-bis(2-hydroxyethyl)amino)propan-2-ol
Cas Number:
6712-98-7
Molecular formula:
C7H17NO3
IUPAC Name:
1-[bis(2-hydroxyethyl)amino]propan-2-ol
Test material form:
other: Vapour or fumes
Details on test material:
- Name of test material (as cited in study report): Diethanolisopropanolamine (DEIPA)
- Substance type: Technical product
- Physical state: Liquid
- Analytical purity: No data
- Impurities (identity and concentrations): No data
- Composition of test material, percentage of components: No data
- Isomers composition: No data
- Purity test date: 8/7/1975
- Lot/batch No.: Not specified
- Expiration date of the lot/batch: Not specified
- Stability under test conditions: Not specified
- Storage condition of test material: Not specified

Test animals

Species:
rat
Strain:
not specified
Sex:
male
Details on test animals or test system and environmental conditions:
TEST ANIMALS
no data

ENVIRONMENTAL CONDITIONS
- Temperature (°C): room temperature
- Humidity (%): No data
- Air changes (per hr): No data
- Photoperiod (hrs dark / hrs light): No data

Administration / exposure

Route of administration:
inhalation: vapour
Type of inhalation exposure:
not specified
Vehicle:
air
Details on inhalation exposure:
GENERATION OF TEST ATMOSPHERE / CHAMBER DESCRIPTION
No data

TEST ATMOSPHERE
No data

VEHICLE
- Composition of vehicle (if applicable): No data
- Concentration of test material in vehicle (if applicable): 16.4 mg/L (approx 3060 ppm)
- Justification of choice of vehicle: No data
- Lot/batch no. (if required): No data
- Purity: No data

TEST ATMOSPHERE (if not tabulated)
No data
Analytical verification of test atmosphere concentrations:
not specified
Duration of exposure:
ca. 7 h
Concentrations:
16.4 mg/L of air or approximately 3060 ppm
No. of animals per sex per dose:
6 males
Control animals:
not specified
Details on study design:
No data
Statistics:
None reported

Results and discussion

Preliminary study:
None reported
Effect levels
Sex:
male
Dose descriptor:
LC50
Effect level:
> 16.4 mg/L air
Based on:
test mat.
Exp. duration:
7 h
Remarks on result:
other: 95% confidence levels not applicable since no deaths occurred
Mortality:
No deaths occured
Clinical signs:
other: None reported
Body weight:
None reported
Gross pathology:
None reported
Other findings:
All animals exhibited eye and nasal irritation which subsided 24 hours after exposure

Applicant's summary and conclusion

Interpretation of results:
not classified
Remarks:
Migrated information Criteria used for interpretation of results: EU
Conclusions:
In an acute inhalation study, no deaths were seen following exposure of 6 males rats to DEIPA saturated air (16.4 mg/L) for 7 hours. An acute inhalaiton LC50 of greater than 16.4 mg/L can be determined.
Executive summary:
In a poorly-reported acute inhalation toxicity study, 6 male rats were exposed to DEIPA saturated air (16.4 mg/L) for 7 hours at room temperature.

No mortality occurred. However, all animals exhibited eye and nasal irritation which had subsided 24-hr after exposure. From the results of this study, an LC50 of greater than 16.4 mg/L for DEIPA in rats can be determined.

Critical details were missing on the test substance identifty (e.g. purity/impurity profile), test methods (including species, number of animals, concentration used, level of examination) and results. Therefore, the findings of this early study should be interpreted with caution.