Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Viscosity

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study with acceptable restrictions
Qualifier:
according to guideline
Guideline:
other: Ubbelohde capillary method
GLP compliance:
no
Type of method:
capillary viscometer (static)
Remarks:
Ubbelohde
Key result
Temp.:
40°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
2.03
Key result
Temp.:
20°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
3.04



























































Temperature



20°C



40°C



1st run



616.99



411.13



2nd run



615.35



143.88



3rd run



615.05



411.53



4th run



616.54



411.66



5th run



615.78



411.53



Mean value of flow time [s]



615.942



411.946



Hagenbach correction [s]



0.082



0.184



Corrected flow time [s]



615.859



411.762



Viscosimeter constant [mm2s-2]



0.004932



0.004932



Kinematic viscosity [mm2s-1]



3.0374



2.0308


Conclusions:
A kinematic viscosity values of 3.04 mm²/s at 20°C and 2.03 mm²/s at 40°C was determined using an appropriate guideline method not according to GLP. This result is considered reliable.

Description of key information

Kinematic Viscosity: 3.04 mm²/s at 20°C and 2.03 mm²/s at 40°C (capillary method)

Key value for chemical safety assessment

Viscosity:
3.04 mm²/s (static)
at the temperature of:
20 °C

Additional information

Kinematic viscosity values of 3.04 mm2/s at 20°C and 2.03 mm2/s at 40°C were determined for the submission substance according to the Ubbelohde capillary method. The results are considered to be reliable and are selected as key.

 

The key result is supported by a predicted kinematic viscosity of 2.4 mm2/s at 20°C, determined using a validated QSAR estimation method. The result is considered to be reliable.

 

In a secondary source to which reliability could not be assigned, a dynamic viscosity value of 3.0 mPa.s at 20°C was reported for the substance.