Administrative data

Link to relevant study record(s)

Description of key information

A manual sieve analysis test indicated that 26.1% by weight of sample had a particle size of < 2000 µm. Using the laser diffraction test on the < 2000 µm sample (with the wet powder module), the Mass Median Aerodynamic Diameter (MMAD) was determined to be 620.607 µm. 0% by volume was seen to be < 10.00 µm.