Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
substances / mixtures which in contact with water emit flammable gases
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
the study does not need to be conducted because the experience in production or handling shows that the substance does not react with water, e.g. the substance is manufactured with water or washed with water
Endpoint:
flammable solids
Data waiving:
study technically not feasible
Justification for data waiving:
the study does not need to be conducted because the substance is a liquid
Endpoint:
pyrophoric liquids
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
the study does not need to be conducted because the substance is known to be stable in contact with air at room temperature for prolonged periods of time (days) and hence, the classification procedure does not need to be applied

Description of key information

Flammability: flammable liquid.

Key value for chemical safety assessment

Flammability:
flammable

Additional information

The flammability study is not required for liquids as flammability is assessed on the basis of flash point.

There is no indication on the basis of structure and experience in handling and use that the substance is pyrophoric (flammable in contact with air) or flammable in contact with water.

Therefore, in accordance with Section 1 of REACH Annex XI, there is no need to conduct further flammability testing

Justification for classification or non-classification

Hexan-1 -ol is classified as a Flam. Liq. 3, H226 (Flammable Liquid and Vapour) according to Regulation (EC) No. 1272/2008. This is on the basis of a measured flash point of 60°C and boiling point of 155°C.