Endpoint:
pH
Type of information:
experimental study
Adequacy of study:
key study
Study period:
10/07/2015 - 10/07/2015
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Justification for type of information:
Experimental test result performed using standard OECD test guidelines

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2015
Report date:
2015

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
other: OECD 122
Principles of method if other than guideline:
The pH determination of test substance was done as per the test guideline OECD 122. The pH of the test solution was determined with the help of pH meter.
GLP compliance:
no

Test material

Constituent 1
Chemical structure
Reference substance name:
Undec-10-enal
EC Number:
203-973-1
EC Name:
Undec-10-enal
Cas Number:
112-45-8
Molecular formula:
C11H20O
IUPAC Name:
undec-10-enal
Test material form:
other: Liquid
Details on test material:
- Name of test material: undec-10-enal
- Molecular weight: 168.278 g/mol
- Molecular formula: C11-H20-O
- Substance type: Organic
- Physical state: Liquid
- Purity: 98.62 %
Specific details on test material used for the study:
- Name of test material: undec-10-enal
- Molecular weight: 168.278 g/mol
- Molecular formula: C11-H20-O
- Substance type: Organic
- Physical state: Liquid
- Analytical purity:98.82% (GLC)
- Lot/batch No.:KC/C11/1412051
- Stability under test conditions: Stable in recommended storage conditions
- Storage condition of test material: Store in cool place. Keep container tightly closed in a dry and well-ventilated place.

Results and discussion

pH value
Key result
pH value:
5.07
Temp.:
29 °C
Concentration:
1 other: % w/v
Remarks on result:
other: No other detail available

Any other information on results incl. tables

TEST RESULTS

Method Details

Observations

Remarks if, any

Guideline

OECD 122

-

 

Method

 

pH Meter

-

Principle of method

 

 

 

 

 

 

 

A pH meter is essentially a voltmeter with high input impedance which measures the voltage of an electrode sensitive to the hydrogen ion concentration, relative to another electrode which exhibits a constant voltage.

-

Temperature of 1% w/v test solution

-

29 °C

pH (RESULT)

 

-

5.07

Inference

1.   Acidic

2.   Basic

3.   Neutral

 

Acidic

 

Applicant's summary and conclusion

Conclusions:
The pH determination of test substance was done as per the test guideline OECD 122. The pH of the test solution was determined with the help ofpH meter. The pH was determine to be 5.07 at 29 °C.
Executive summary: