Registration Dossier

Diss Factsheets

Administrative data

Endpoint:
flash point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2005
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: study performed under GLP and in accordance with Czechian testing methods (similar to OECD-/EU-testing guidelines)
Cross-reference
Reason / purpose for cross-reference:
reference to same study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2005
Report date:
2005

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
ISO No., other: Method V Flash Point (Regulation of the Ministry of Interior of Czech Republic No. 164/2004 - identical with method A.9 of Directive 92/69/EEC)
Deviations:
no
GLP compliance:
yes
Type of method:
closed cup

Test material

Constituent 1
Details on test material:
- Name of test material (as cited in study report): 4-butyrobetain (BUBET)
- Molecular formula: C7H15NO2
- Molecular weight: 145.20 g/mol
- Physical state: colourless solution

Results and discussion

Flash point
Flash point:
> 107 °C
Atm. press.:
980 mBar
Remarks on result:
other: test performed with an aqueous solution of test item

Applicant's summary and conclusion

Conclusions:
The flash point of an aqeous solution was determined to be 107°C at 980 mbar. The concentrated material could not be measured due to its high viscosity.
Executive summary:

The test was performed in 2005 under GLP according to the Czechian testing method V (similar to method A.9 of Directive 92/69/EEC).