Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
flammable solids
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
other:
Justification for type of information:
JUSTIFICATION FOR DATA WAIVINGThe substance is marketed in water solution and therefore the flammability of the substance has been analysed through the flash point test. Determination of flash point of test substance was performed, according to the EU A.9 method, with GLP (Closed cup method). The test item had not flash point up to the boiling point (90 ºC).
Reason / purpose for cross-reference:
reference to other study
Endpoint:
pyrophoric solids
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
the study does not need to be conducted because the substance is known to be stable in contact with air at room temperature for prolonged periods of time (days) and hence, the classification procedure does not need to be applied
Justification for type of information:
JUSTIFICATION FOR DATA WAIVINGThe study does not to be conducted because the test substance is known to be stable in contact with air at room temperature for prolonged periods of time (days) and hence, the classification procedure does not need to be applied. The test was not performed experimentally because practical experience exists at the sponsor and the test facility, e.g. when handling small amounts of the test substance repeatedly in air during testing. The test substance is therefore regarded as not being pyrophoric.
Endpoint:
substances / mixtures which in contact with water emit flammable gases
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
the study does not need to be conducted because the experience in production or handling shows that the substance does not react with water, e.g. the substance is manufactured with water or washed with water
Justification for type of information:
JUSTIFICATION FOR DATA WAIVINGFlammability in contact with water: The practical experience of the sponsor and the test facility shows that no gases are developed, when the test substance is in contact with water. The test substance is therefore regarded as not being flammable in contact with water.

Description of key information

Flammability solids: Data waiving (other justification): The substance is marketed in water solution and therefore the flammability of the substance has been analysed through the flash point test. Determination of flash point of test substance was performed, according to the EU A.9 method, with GLP (Closed cup method). The test item had not flash point up to the boiling point (90 ºC).

Key value for chemical safety assessment

Flammability:
non flammable

Additional information

Flammability solids: Data waiving (other justification): The substance is marketed in water solution and therefore the flammability of the substance has been analysed through the flash point test. Determination of flash point of test substance was performed, according to the EU A.9 method, with GLP (Closed cup method). The test item had not flash point up to the boiling point (90 ºC).

Pyrophoric properties: Data waiving (other justification):The test was not performed experimentally because practical experience exists at the sponsor and the test facility, e.g. when handling small amounts of the test substance repeatedly in air during testing. The test substance is therefore regarded as not being pyrophoric.

Flammability in contact with water: Data waiving (other justification): The practical experience of the sponsor and the test facility shows that no gases are developed, when the test substance is in contact with water. The test substance is therefore regarded as not being flammable in contact with water.

Justification for classification or non-classification

Based on the available data, the substance is not classified as flammable in accordance with CLP Regulation (EC) no. 1272/2008.