Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
March 23, 1992 - June 1, 1992
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Version / remarks:
2002
Qualifier:
according to guideline
Guideline:
ISO No., other: ASTM D93
GLP compliance:
yes (incl. QA statement)
Type of method:
closed cup
Flash point:
179 °C
Atm. press.:
1 atm
Interpretation of results:
GHS criteria not met
Conclusions:
The flashpoint of the substance was determined to be 179 degrees Celsius, using a Pensky-Martens closed cup apparatus.

Description of key information

The flashpoint of the substance was determined to be 179 degrees Celsius, using a Pensky-Martens closed cup apparatus.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
179 °C

Additional information