Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Viscosity

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Study period:
From 13-04-2022 to 15-04-2022
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Test Guideline 114 (Viscosity of Liquids)
Deviations:
no
Qualifier:
according to guideline
Guideline:
other: CIPAC MT 22
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
capillary viscometer (static)
Key result
Temp.:
20°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
3
Key result
Temp.:
40°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
2.65

Table 1. The obtained viscosity values at 20ºC are as follows: 

























Replication NoViscosity of
Test Item
mm2/s
Mean Viscosity of
Test Item
mm2/s
RSD (%)
12.99953.000.099
23.0025
32.9966

Table 2. The obtained viscosity values at 40ºC are as follows: 

























Replication NoViscosity of
Test Item
mm2/s
Mean Viscosity of
Test Item
mm2/s
RSD (%)
12.65872.650.172
22.6527
32.6497
Conclusions:
The determined kinematic viscosity of the tested material is 3.0 mm2/s at 20ºC and 2.65 mm2/s at 40ºC.
Executive summary:

The determination of viscosity of the test item was performed according to OECD Guideline 114 and CIPAC MT 22, using a capillary viscometer (U-tube viscometer size A) to measure the kinematic viscosity. The test item was initially analyzed for dynamic viscosity using rotational viscometer at 20°C and 40°C. The torque % was found less than 10% and the viscosity was found below 100 mPa. s at 20°C and 40°C temperatures. Thus, the test item was finally analyzed for kinematic viscosity using U-tube viscometer size A. The experiment was conducted in three replications at 20ºC and 40ºC. The determined average kinematic viscosity of the test item was 3.0 mm2/s at 20ºC and 2.65 mm2/s at 40ºC.

Description of key information

Key study: OECD Guideline 114. GLP study: The kinematic viscosity of the tested material is 3.0 mm2/s at 20ºC and 2.65 mm2/s at 40ºC.

Key value for chemical safety assessment

Viscosity:
2.65 mm²/s (static)
at the temperature of:
40 °C

Additional information