Administrative data

First-aid measures

Description of first aid measures:

General advice: Remove contaminated clothing immediately and dispose of safely.

If inhaled: When spray fog inhaled, seek medical aid immediately and show the physician the packing or the packing label.

In case of skin contact: In case of contact with skin wash off immediately with plenty of water.

In case of eye contact: In case of contact with eyes rinse thoroughly with plenty of water and seek medical advice

If swallowed: When swallowed seek medical aid immediately and show the physician the packaging or the label of the packaging.

Most important symptoms and effects, both acute and delayed

Symptoms: No information available.

Hazards: No information available.

Indication of any immediate medical attention and special treatment needed

Treatment: Treat symptomatically.

Fire-fighting measures

Extinguishing media:

Suitable extinguishing media: Extinguishing measures to suit surroundings

Special hazards arising from the substance or mixture:

In case of combustion, evolution of dangerous gases possible.

Advice for firefighters: Special protective equipment: Use self-contained breathing apparatus.

Further information: Fire residues and contaminated firefighting water must be disposed of in accordance with the local regulations.

Accidental release measures

Personal precautions, protective equipment and emergency procedures:

Use personal protective clothing.

Environmental precautions:

Do not allow to enter drains or waterways.

Methods and materials for containment and cleaning up:

General advice: Pick up with absorbent material (eg sand, kieselgur, acid binder, universal binder, sawdust).

Clean contaminated floors and objects thoroughly, observing environmental regulations

When picked up, treat material as prescribed under heading "Disposal".

Reference to other sections:

Information regarding Safe handling, see chapter 7. Information regarding personal protective measures see, chapter 8. Information regarding Waste Disposal, see chapter 13.

Handling and storage

Precautions for safe handling:

Advice on safe handling (industrial scale):Avoid formation of aerosols. Provide exhaust ventilation.

Advice on protection against fire and explosion:Take precautionary measures against electrostatic loading. Observe the general rules of industrial fire protection

Conditions for safe storage, including any incompatibilities:

Requirements for storage rooms and vessels: Keep only in the original container

Further information on storage conditions: Keep container tightly closed and dry

Specific end use(s):

No data available.

Transport information

Land transport (UN RTDG/ADR/RID)

UN number:
UN3080
Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

UN number:
UN3080
Shipping information
Proper shipping name and description:
ISOCYANATES, TOXIC, FLAMMABLE, N.O.S.
Chemical name:
(trans-4-Methylcyclohexylisocyanate)
Labels:
6.1 (3)
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

UN number:
UN3080
Shipping information
Proper shipping name and description:
ISOCYANATES, TOXIC, FLAMMABLE, N.O.S.
Chemical name:
(trans-4-Methylcyclohexylisocyanate)
Labels:
6.1 (3)
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Personal protection equipment

(IMPORTANT: to be adapted following the workplace risk assessment.)

General protective measures:

Avoid contact with eyes and skin. A workplace risk assessment must be carried out in order to determine the correct engineering control measures and personal protective equipment. Protective clothing should be selected specifically for the working place, depending on concentration and quantity of the hazardous substances handled. The resistance of the protective clothing to chemicals should be ascertained with the respective supplier.

Industrial workplace

Respiratory protection:

Use respiratory protection in case of insufficient exhaust ventilation or prolonged exposure. Multi-purpose filter ABEK Powered Air-purifying respirator (PAPR) - mounted airhat

Hand protection:

In splash contact: Viton® gloves. Glove material : Vitoject® (KCL) Layer thickness : 0,7 mm Permeation time : > 10 min

The protective gloves to be used must comply with the specifications of EC directive 89/686/EEC and the resultant standart EN374. This recommandation applies only to the product stated in this safety data sheet and supplied by us as well as to the purpose specified by us. When dissolving in or mixing with other substances and under conditions deviating from those stated in EN374 please contact the supplier of CE-approved gloves.

Eye/face protection:

tightly fitting safety glasses

Body Protection:

Protective clothing Disposable suit (Typ 4 or Typ 6)

Additional advice on system design:

Use under strictly controlled conditions.

Hygiene measures:

Do not eat, drink or smoke during work time. Keep away from foodstuffs and beverages. After worktime and during work intervals the affected skin areas must be thoroughly cleaned.

Laboratory

Respiratory protection:

Handling in a fume cupboard.

Hand protection:

In splash contact:

Nitrile rubber gloves.

Eye/face protection:

Safety glasses with side protection shield.

Body Protection:

Dedicated working clothes.

Hygiene measures:

Wash hands before breaks and at the end of workday.

Stability and reactivity

Reactivity:No decomposition if used as directed.

Chemical stability:No decomposition if stored normally.

Possibility of hazardous reactions:No hazardous reactions known.

Conditions to avoid: No data available.

Incompatible materials: None known.

Hazardous decomposition products:Carbon monoxide and carbon dioxide Nitrogen oxides (NOx)

Disposal considerations

Waste treatment methods:

Product: In accordance with regulations for special waste, must be taken to an authorised special waste incineration plant. Harmful emissions must be removed by flue gas scrubbing

Uncleaned packaging: Packaging that cannot be cleaned should be disposed off as product waste