First-aid measures

Description of first aid measures

following inhalation : Remove victim to fresh air and keep at rest in a position comfortable for breathing. Call emergency services (physician, hospital).
following skin contact : Wash off with soap and plenty of water. Remove all contaminated clothing and rinse exposed skin with plenty of water and soap. Consult a physician.
following eye contact : Rinse with large quantities of running water for at least few minutes. Remove contact lenses if present and easy to do – continue rinsing. If situation requires arrange seek medical assistance.
following ingestion : Rinse mouth with water Seek medical attention

Most important symptoms and effects, both acute and delayed : No data available
following inhalation : No data available
following skin contact : No data available
following eye contact : No data available
following ingestion : No data available

Indication of any immediate medical attention and special treatment needed
following inhalation : No data available
following skin contact : No data available
following eye contact : No data available
following ingestion : No data available

Fire-fighting measures

Fire-fighting measures

Extinguishing media
Suitable extinguishing media : water, dry chemical or carbon dioxide
Unsuitable extinguishing media : none

Special hazards arising from the substance or mixture
Hazardous combustion products : toxic and corrosive gaz can be produced (CO, CO2, NOx)

Advice for fire-fighters Protection or removal of flammable materials nearby. Wearing protective equipment: coveralls, boots, gloves, protective equipment for eye and face, and breathing apparatus (SCBA)

Accidental release measures

Personal precautions, protective equipment and emergency procedures

For non-emergency personnel :
Use personal protective equipment : . Avoid dust formation. Avoid breathing dust. Ensure adequate ventilation.
Protective equipment : dust mask, safety goggles, safety glasses, body protection
Emergency procedures : Keep away from ignition sources, ventilate, prevent access to unauthorized persons.

For emergency responders
Wear self contained breathing apparatus for fire fighting if necessary. Suitable fabric for personal protective clothing

Environmental precautions
Do not allow to enter drainage system, surface or ground water.
Inform respective authorities in case product reaches water or sewage system.

Methods and material for containment and cleaning up
For containment:
Establishment of a protective covering of drains.
For cleaning up:
Ensure adequate ventilation. Collect mechanically. Avoid dust formation. Use of non sparking tools and equipment (if applicable). Keep in suitable, closed containers for disposal (See section 13). Wet clean the residues and then rinse out the soil with water. Collect all waste for later disposal.

Inappropriate containment or clean up techniques : Never use stainless steel container

Handling and storage

HANDLING AND STORAGE

Precautions for safe handling
Recommendation for safe handling:
- Use under hood, laminar flow extractor
- Keep containers tightly sealed.
General advice on occupational health:
- Do not eat, drink or smoke in work areas
- Wash your hands after each use
-Remove contaminated clothing and protective equipment before entering an eating area

Conditions for safe storage, including any incompatibilities
Technical measures and storage conditions: Store in cool place. Keep container tightly closed in a dry and well ventilated place.
Packaging materials: The substance can be packaged in two plastic bags and these in plastic drums but not in stainless steel container

Transport information

Land transport (UN RTDG/ADR/RID)

UN number:
none
Shippingopen allclose all
SpecialProvisionsopen allclose all

Inland waterway transport (UN RTDG/ADN(R))

UN number:
none
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

UN number:
none
Shippingopen allclose all
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

UN number:
none
Shippingopen allclose all
Remarksopen allclose all

Additional transport information

Additional information
Special provisions / remarks / other:
Transport in bulk according to Annex II of MARPOL 73/78 and the IBC Code

Exposure controls / personal protection

Control parameters
Occupational Exposure limit values : no data available
Derived No Effect Levels (DNELs) : no data available
Derived Minimal Effect Levels (DMELs) : no data available
Predicted No Effect Concentrations (PNECs) : no data available
Information on monitoring procedures : No data available

Exposure controls
Appropriate engineering controls:
Product related measures to prevent exposure: no data available
Structural measures to prevent exposure: no data available
Organisational measures to prevent exposure: no data available
Technical measures to prevent exposure: no data available

Personal protection equipment :
- Eye and face protection: safety glasses, face-shields
- Skin protection:
- Hand protection: The selected protective gloves have to satisfy the specifications of EU Directive 89/686/EEC and the
standard EN 374 derived from it. Handle with protective gloves. The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Check the permeability prior to each renewed use of the glove.
- Body protection:
Choose body protection according to the amount of the substance to be handled.
Protective work clothing
Protective clothing should be selected specifically for the working place.
- Respiratory protection:
Where risk assessment shows air-purifying respirators are appropriate use a dust mask type N95 (US) or
type P1 (EN 143) respirator. Use respirators and components tested and approved under appropriate
government standards such as NIOSH (US) or CEN (EU).
Thermal hazards: Not applicable

Environmental exposure controls:
Product related measures to prevent exposure : no data available
Instruction measures to prevent exposure : no data available
Organisational measures to prevent exposure : no data available
Technical measures to prevent exposure : no data available

Stability and reactivity

Reactivity : This substance reacts with organic bases, mineral bases, oxidants and metals
Chemical stability : Stable under normal conditions of use
Possibility of hazardous reactions : No data available
Conditions to avoid : No data available
Incompatible material : No data available
Hazardous decomposition products : see section 5. If the substance is overheated.

Disposal considerations

Waste treatment methods

Product / Packaging disposal:
Dispose of waste in authorized plant, in accordance with the applicable local and national laws.
Waste treatment-relevant information:
Dispose of waste in authorized plant, in accordance with the applicable local and national laws.
Sewage disposal-relevant information:
Dispose of waste in authorized plant, in accordance with the applicable local and national laws.
Other disposal recommendations: No data available
Any special precautions for any recommended waste treatment option : See sections 5 and 8

Additional information : No further information