Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

First-aid measures

Eye contact: RInse thoroughly with plenty of water for at least 15 minutes and consult a physician.
Skin contact: Take off all contaminated clothing immediately. Wash off immediately with plenty of water for at least 20 minutes. Consult a physician if necessary.
Ingestion: Rinse mouth with plenty of water. Call a physician immediately.
Inhalation: Take person to fresh air. Rest in half-sitting position. Consult a physician.

Fire-fighting measures

All extinguishing media are suitable.
Toxic and irritating gases/fumes may be given off during burning or thermal decomposition. Use extinguishing measures that are appropriate to local circumstances and the surrounding environment. Collect contaminated fire extinguishing water separately. This must not be discharged into drains.
In the event of fire, wear self-contained breathing apparatus. Regular fire intervention clothes.

Accidental release measures

Personal : Cleanup personnel must use appropriate personal protective equipment. Observe normal precautions when handling chemicals.
Environmental : Avoid subsoil penetration. Do not flush into surface water or sanitary sewer system. If the product contaminates rivers and lakes or drains inform respective authorities.
Methods for cleaning up: Collect spilled material with vacuum cleaner or sweep up. Collect the product in a plastic vessel. Carefully collect leftovers. Collect spilled product in another vessel and carry off as chemical waste.
See also in sections 'Exposure controls/personal protection' and 'Disposal considerations'

Handling and storage

Handling: Avoid dust formation. Avoid contact with skin and eyes. Do not ingest. Prevent product from diffusing. No dust explosion danger.
Storage: Prevent product from diffusing. Keep in a dry place. Keep container tightly closed. Keep container in a well-ventilated place. Store away from strong acids.

Transport information

Land transport (UN RTDG/ADR/RID)

UN number:
3077
Shipping information
Proper shipping name and description:
ENVIRONMENTALLY HAZARDOUS SUBSTANCE, SOLID, N.O.S. (Barium Strontium Bromide Fluoride Europeum gedopeerd)
Chemical name:
Barium Strontium Bromide Fluoride Europeum gedopeerd
Language:
Dutch
Labels:
label no.9
risk no.90
SpecialProvisionsopen allclose all

Inland waterway transport (UN RTDG/ADN(R))

UN number:
3077
Shipping information
Proper shipping name and description:
ENVIRONMENTALLY HAZARDOUS SUBSTANCE, SOLID, N.O.S. (Barium Strontium Bromide Fluoride Europeum gedopeerd)
Chemical name:
Barium Strontium Bromide Fluoride Europeum gedopeerd
Language:
Dutch
Labels:
label no.9
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

UN number:
3077
Shipping information
Proper shipping name and description:
ENVIRONMENTALLY HAZARDOUS SUBSTANCE, SOLID, N.O.S. (Barium Strontium Bromide Fluoride Europeum gedopeerd)
Chemical name:
Barium Strontium Bromide Fluoride Europeum gedopeerd
Labels:
label no.9
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

UN number:
3077
Shipping information
Proper shipping name and description:
ENVIRONMENTALLY HAZARDOUS SUBSTANCE, SOLID, N.O.S. (Barium Strontium Bromide Fluoride Europeum gedopeerd)
Chemical name:
Barium Strontium Bromide Fluoride Europeum gedopeerd
Labels:
label no. 9MI
Special provisions / remarks
Remarks:
Packaging instruction for ICAO/IATA: 911
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Instructual measures to prevent exposure: Employees should wash their hands and face before eating, drinking, or using tobacco products. Keep away from foodstuffs, drinks and tobacco.
Technical measures to prevent exposure: Ensure adequate ventilation. The subsatnce is used only by trained professionals under restricted conditions in almost completely closed systems.
Repiratory protection: In case of heavy air pollution a dust mask P2 is to be worn.
Hand protection: Use chemical resistant gloves. See details on SDS
Eye protection: Safety glasses.
Body protection: Wear disposable overalls.
Personal protective equipment: Emplyees should wash their hands and face before eating, drinking or using tobacco products.

Stability and reactivity

Reactivity: not to be expected under normal conditions of temperature and pressure.
Stability: stable under normal conditions of storage and use.
Hazardous reactions: reacts with acids.
Conditions to avoid: avoid generating airborne dust. avoid contact with acids. remove all chemicals and rinse the processing tanks thoroughly with water before using any cleansing products.
Hazardous decomposition products: Toxic and irritating gases/fumes may be given off during burning or thermal decomposition.

Disposal considerations

1. Waste disposal methods: Do not release into drain. Collect for removal by a license waste contractor. Effluent regulations/discharge/treatment/contents may vary from one area to another. Please consult the local regulations regarding the disposal of this material.
2. Empty containers: As the packaging can be contaminated with product residues, please obeserve the warnings of the label even when the container is empty.
For waste resulting from this product, it is recommended to use European Waste Code: 20 01 17 (photochemicals).

Industry - Possibility of recovery/recycling: [611] Recovery by mechanical collection.
Industry - Possibility of neutralisation: [633] Neutralisation by water treatment.
Industry - Possibility of destruction: controlled discharge: Not recommended.
Industry - Possibility of destruction - incineration: Not applicable.
Industry - Possibility of destruction - water purification: The product is fully ionised in water. When sufficient
sulfate is present in the solution, barium, strontium and
lead will precipitate. The precipitate will be removed by
mechanical means.
Industry - Possibility of destruction - other: None.
Public at large - Possibility of recovery/recycling: Not applicable.
Public at large - Possibility of neutralisation: Not applicable.
Public at large - Possibility of destruction: controlled discharge: Not applicable.
Public at large - Possibility of destruction - incineration: Not applicable.
Public at large - Possibility of destruction - water purification: Not applicable.
Public at large - Possibility of destruction - others: Not applicable.