Endpoint:
boiling point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2009
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: The study was performed according to guideline

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2009
Report date:
2009

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
other: ASTM E2550-07 Standard Test Method for Thermal Stability by Thermogravimetry
Deviations:
no
GLP compliance:
no
Remarks:
ISO 9001/2000 Certified
Type of method:
other: thermogravimetric

Test material

Constituent 1
Chemical structure
Reference substance name:
Phosphorodithioic acid, mixed O,O-bis(iso-Bu and pentyl) esters, zinc salts
EC Number:
270-608-0
EC Name:
Phosphorodithioic acid, mixed O,O-bis(iso-Bu and pentyl) esters, zinc salts
Cas Number:
68457-79-4
Molecular formula:
{[(iso-C4H9O)0.64(C5H11O)0.36]PS2}2Zn - neutral, {[(iso-C4H9O)0.64(C5H11O)0.36]PS2}6Zn4O - basic
IUPAC Name:
Phosphorodithioic acid, mixed O,O-bis(iso-Bu and pentyl) esters, zinc salts

Results and discussion

Boiling pointopen allclose all
Decomposition:
yes
Decomp. temp.:
216 °C
Remarks on result:
other: 67.1% of the test substance decomposes at 216 deg. C
Decomposition:
yes
Decomp. temp.:
456 °C
Remarks on result:
other: 3.9% of the test substance decomposes at 456 deg. C

Any other information on results incl. tables

TGA data show there were two thermal events resulting in weight loss associated with sample decomposition. These thermal events occurred at derivative peak values of 216 0C and 456 0C and account for weight losses of 67.1% and 3.9%, respectively. The overall onset of sample weight loss occurred at approx.  211oC. A residue remained at 600 0C accounting for 29% of the material. A TGA thermograph is attached as Figure 1.

Table 1: Results of TGA Analysis

Derivative Peak (oC)

% Weight Loss

 216

 67.1

 456

  3.9

Residue at  600 oC

 29.0

     

Applicant's summary and conclusion

Conclusions:
Analysis by TGA indicates the test substance decomposes before boiling. The test material showed weight loss associated with decomposition at temperatures of 216 C and 456 C.
Executive summary:

A thermogravimetric analysis performed according to the ASTM E2550 -07 guideline indicates the test substance decomposes before boiling.

The test material was heated under nitrogen up to 600 oC. Examination of the TGA curve shows that weight loss associated with sample decomposition occurred. The onset of weight loss occurred at approx. 211 oC. There were two main thermal events at derivative peak values of  216 and 456 oC corresponding to weight loss values of 67.1 and 3.9%, respectively. A residue remained at  600 oC equivalent to 29% of the material.