Physical & Chemical properties

Flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flammable liquids: obsolete as covered by section 'Flash point'
Data waiving:
study technically not feasible
Justification for data waiving:
the study does not need to be conducted because the substance is a liquid
Reason / purpose for cross-reference:
reference to other study

Description of key information




Flammability: non-flammable liquid; experimentally determined flash point > 60 °C.




Key value for chemical safety assessment

Flammability:
not classified

Additional information




As the substance is a liquid, the relevant test for flammable properties is the Flash Point measurement. A fully reliable experimental study is presented under IUCLID section 4.11.




Justification for classification or non-classification

According to the results of the test on the flash point, the test item is classified as follows:


CLP (Regulation EC 127212008 Annex 1: 2.6): With a measured flash point > 60 °C, the test item does NOT have to be classified as flammable liquid.


GHS: with a measured flash point between 60 and 93°C, the test item is classified in category 4.


UN Transport Regulation: With a measured flash point> 60 °C, the test item does NOT have to be classified as flammable liquid according to the UN Transport Regulation.