Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flammability

Currently viewing:

Administrative data

Endpoint:
flammability
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: guidline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2009
Report date:
2009

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
other: Fire propagation rate (UN), N1
Principles of method if other than guideline:
Recommendations on the Transport of Dangerous Goods, Manual of Tests and Criteria,
2nd revised edition, Part III, Test N.1, Section 33.2.1.4
GLP compliance:
no

Test material

Constituent 1
Chemical structure
Reference substance name:
α-chloro-4-fluoroacetophenone
EC Number:
207-256-4
EC Name:
α-chloro-4-fluoroacetophenone
Cas Number:
456-04-2
Molecular formula:
C8H6ClFO
IUPAC Name:
2-chloro-1-(4-fluorophenyl)ethan-1-one
Test material form:
other: solid
Details on test material:
- Name of test material (as cited in study report): Fluorachloracetophenon QB 063 v. 12.11.09
- Analytical purity: not documented

Results and discussion

Flammable solids
Test procedure:
burning time (test type not further specified)
Remarks:
or specified in description of method (migrated information)
Remarks on result:
other: Brief burning followed by rapid extinction
Pyrophoric solids
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record.
Pyrophoric liquids
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record.
Substances / mixtures which in contact with water emit flammable gases
Remarks on result:
no reaction with water observed
Remarks:
corresponding to 'no' in migrated source record.

Any other information on results incl. tables

1. Preliminary test: Burning time ( 200 mm test distance): Brief burning followed by rapid extinction. Therefore, the preliminary screening test is negative. Because of the result of the preliminary test the test substance is not considered a flammable solid of division 4.1.

Applicant's summary and conclusion