- General information
Keep warm, position comfortably and cover well.
Keep warm, position comfortably and cover well.
Seek immediate medical advice
- After inhalation Supply fresh air; consult doctor in case of symptoms.
- After skin contact
Instantly wash with water and soap and rinse thoroughly.
- After eye contact
Rinse opened eye for several minutes under running water.
Seek medical treatment.
- After swallowing
Rinse mouth without swallowing, do not induce vomiting
Administer medicinal carbon
Do not induce vomiting; instantly call for medical help.
Most important symptoms and effects, both acute and delayed No further relevant information available.
Indication of any immediate medical attention and special treatment needed
No further relevant information available.

Fire-fighting measures

Extinguishing media
- Suitable extinguishing agents
CO2,extinguishing powder or water jet. Fight larger fires with water jet or alcohol-resistant foam.
For safety reasons unsuitable extinguishing agents : Water with a full water jet.
Special hazards arising from the substance or mixture
Formation of poisonous gases during heating or in fires.
Can be released in case of fire
Nitrogen oxides (NOx)
Carbon monoxide (CO)
Hydrogen chloride (HCl)
Advice for firefighters
- Protective equipment:
Do not inhale explosion gases or combustion gases.
Wear full protective suit.
Put on breathing apparatus.

Accidental release measures

Personal precautions, protective equipment and emergency procedures
Avoid causing dust.
Environmental precautions:
Do not allow to enter drainage system, surface or ground water.
Inform respective authorities in case product reaches water or sewage system.
Methods and material for containment and cleaning up:
Ensure adequate ventilation.
Collect mechanically.
Dispose of contaminated material as waste according to item 13.

Handling and storage

Precautions for safe handling
Prevent formation of dust.
Provide suction extractors if dust is formed.
- Information about protection against explosions and fires:
Have fire extinguishing equipment ready in case of nearby fire.
Dust can combine with air to form an explosive mixture.
Conditions for safe storage, including any incompatibilities
- Storage
- Requirements to be met by storerooms and containers: No special requirements.
- Information about storage in one common storage facility: Store away from foodstuffs.
- Further information about storage conditions: Keep container tightly sealed.
Specific end use(s) No further relevant information available.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all
Shippingopen allclose all
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Exposure controls
- Personal protective equipment
- General protective and hygienic measures
Avoid contact with the eyes and skin.
Take off immediately all contaminated clothing
Wash hands during breaks and at the end of the work.
Keep away from foodstuffs, beverages and food.
- Breathing equipment: Use breathing protection in case of insufficient ventilation.
- Protection of hands:
The glove material has to be impermeable and resistant to the product/ the substance/ the preparation.
Due to missing tests no recommendation to the glove material can be given for the product/ the preparation/
the chemical mixture.
Selection of the glove material on consideration of the penetration times, rates of diffusion and the
degradation
- Material of gloves
The selection of the suitable gloves does not only depend on the material, but also on further marks of quality
and varies from manufacturer to manufacturer.
- Penetration time of glove material
The exact break trough time has to be found out by the manufacturer of the protective gloves and has to be
observed.
- Eye protection: Safety glasses recommended during refilling
- Body protection: Light weight protective clothing

Stability and reactivity

Disposal considerations